Fortron Source PM202-12BN1 View full datasheet Close datasheet
|
Medical Power Supplies, 150 W
|
Power Supply |
Efficiency |
At 100% load / 25°C |
91 % |
|
Typ (Output) |
DC |
Range |
12V |
|
|
|
Current |
12,5 A |
|
|
|
Output Ripple & Noise Max |
120 mV |
|
Output wattage |
150 W |
Mechanical / Environment |
Dimensions |
Form factor |
Open Frame (U Bracket) |
|
|
Height |
38 mm |
Certificates / Conformities |
Additional certificates / compliance approvals |
CB, CSA C22.2 No. 62368-1, EN 55011, EN 55024, EN 55032, EN 60601-1-2, EN 61000-3-2, EN 61000-3-3, EN 61000-4-2 (Electrostatic Discharge), EN 61000-4-3, EN 61000-4-4 (EFT), EN 61000-4-5 (2 kV Surge Protection), EN 61000-4-6, EN 61000-4-8, EN 61000-4-11, TUV 60601 |
Fortron Source PM202-12CN1 View full datasheet Close datasheet
|
Medical Power Supplies, 200 W
|
Power Supply |
Efficiency |
At 100% load / 25°C |
91 % |
|
Typ (Output) |
DC |
Range |
12V |
|
|
|
Current |
16,67 A |
|
|
|
Output Ripple & Noise Max |
120 mV |
|
Output wattage |
200 W |
Mechanical / Environment |
Dimensions |
Form factor |
Open Frame (Housing) |
|
|
Height |
500 mm |
Certificates / Conformities |
Additional certificates / compliance approvals |
CB, CSA C22.2 No. 62368-1, EN 55011, EN 55024, EN 55032, EN 60601-1-2, EN 61000-3-2, EN 61000-3-3, EN 61000-4-2 (Electrostatic Discharge), EN 61000-4-3, EN 61000-4-4 (EFT), EN 61000-4-5 (2 kV Surge Protection), EN 61000-4-6, EN 61000-4-8, EN 61000-4-11, TUV 60601 |
Fortron Source PM202-13-1BN1 View full datasheet Close datasheet
|
Medical Power Supplies, 150 W
|
Power Supply |
Efficiency |
At 100% load / 25°C |
91 % |
|
Typ (Output) |
DC |
Range |
18V |
|
|
|
Current |
8,34 A |
|
|
|
Output Ripple & Noise Max |
180 mV |
|
Output wattage |
150 W |
Mechanical / Environment |
Dimensions |
Form factor |
Open Frame (U Bracket) |
|
|
Height |
38 mm |
Certificates / Conformities |
Additional certificates / compliance approvals |
CB, CSA C22.2 No. 62368-1, EN 55011, EN 55024, EN 55032, EN 61000-3-2, EN 61000-3-3, EN 61000-4-2 (Electrostatic Discharge), EN 61000-4-3, EN 61000-4-4 (EFT), EN 61000-4-5 (2 kV Surge Protection), EN 61000-4-6, EN 61000-4-8, EN 61000-4-11, TUV 60601, UL 60950-1 |
Fortron Source PM202-13-1CN1 View full datasheet Close datasheet
|
Medical Power Supplies, 200 W
|
Power Supply |
Efficiency |
At 100% load / 25°C |
91 % |
|
Typ (Output) |
DC |
Range |
18V |
|
|
|
Current |
11,12 A |
|
|
|
Output Ripple & Noise Max |
180 mV |
|
Output wattage |
200 W |
Mechanical / Environment |
Dimensions |
Form factor |
Open Frame (Housing) |
|
|
Height |
50 mm |
Certificates / Conformities |
Additional certificates / compliance approvals |
CB, CSA C22.2 No. 62368-1, EN 55011, EN 55024, EN 55032, EN 61000-3-2, EN 61000-3-3, EN 61000-4-2 (Electrostatic Discharge), EN 61000-4-3, EN 61000-4-4 (EFT), EN 61000-4-5 (2 kV Surge Protection), EN 61000-4-6, EN 61000-4-8, EN 61000-4-11, TUV 60601, UL 60950-1 |
Fortron Source PM202-13BN1 View full datasheet Close datasheet
|
Medical Power Supplies, 150 W
|
Power Supply |
Efficiency |
At 100% load / 25°C |
91 % |
|
Typ (Output) |
DC |
Range |
15V |
|
|
|
Current |
10 A |
|
|
|
Output Ripple & Noise Max |
150 mV |
|
Output wattage |
150 W |
Mechanical / Environment |
Dimensions |
Form factor |
Open Frame (U Bracket) |
|
|
Height |
38 mm |
Certificates / Conformities |
Additional certificates / compliance approvals |
CB, CSA C22.2 No. 62368-1, EN 55011, EN 55024, EN 55032, EN 61000-3-2, EN 61000-3-3, EN 61000-4-2 (Electrostatic Discharge), EN 61000-4-3, EN 61000-4-4 (EFT), EN 61000-4-5 (2 kV Surge Protection), EN 61000-4-6, EN 61000-4-8, EN 61000-4-11, TUV 60601, UL 60950-1 |
Fortron Source PM202-13CN1 View full datasheet Close datasheet
|
Medical Power Supplies, 200 W
|
Power Supply |
Efficiency |
At 100% load / 25°C |
91 % |
|
Typ (Output) |
DC |
Range |
15V |
|
|
|
Current |
13,34 A |
|
|
|
Output Ripple & Noise Max |
150 mV |
|
Output wattage |
200 W |
Mechanical / Environment |
Dimensions |
Form factor |
Open Frame (Housing) |
|
|
Height |
50 mm |
Certificates / Conformities |
Additional certificates / compliance approvals |
CB, CSA C22.2 No. 62368-1, EN 55011, EN 55024, EN 55032, EN 61000-3-2, EN 61000-3-3, EN 61000-4-2 (Electrostatic Discharge), EN 61000-4-3, EN 61000-4-4 (EFT), EN 61000-4-5 (2 kV Surge Protection), EN 61000-4-6, EN 61000-4-8, EN 61000-4-11, TUV 60601, UL 60950-1 |
Fortron Source PM202-14BN1 View full datasheet Close datasheet
|
Medical Power Supplies, 150 W
|
Power Supply |
Efficiency |
At 100% load / 25°C |
91 % |
|
Typ (Output) |
DC |
Range |
24V |
|
|
|
Current |
6,25 A |
|
|
|
Output Ripple & Noise Max |
240 mV |
|
Output wattage |
150 W |
Mechanical / Environment |
Dimensions |
Form factor |
Open Frame (U Bracket) |
|
|
Height |
38 mm |
Certificates / Conformities |
Additional certificates / compliance approvals |
CB, CSA C22.2 No. 62368-1, EN 55011, EN 55024, EN 55032, EN 61000-3-2, EN 61000-3-3, EN 61000-4-2 (Electrostatic Discharge), EN 61000-4-3, EN 61000-4-4 (EFT), EN 61000-4-5 (2 kV Surge Protection), EN 61000-4-6, EN 61000-4-8, EN 61000-4-11, TUV 60601, UL 60950-1 |
Fortron Source PM202-14CN1 View full datasheet Close datasheet
|
Medical Power Supplies, 200 W
|
Power Supply |
Efficiency |
At 100% load / 25°C |
91 % |
|
Typ (Output) |
DC |
Range |
24V |
|
|
|
Current |
8,34 A |
|
|
|
Output Ripple & Noise Max |
240 mV |
|
Output wattage |
200 W |
Mechanical / Environment |
Dimensions |
Form factor |
Open Frame (Housing) |
|
|
Height |
50 mm |
Certificates / Conformities |
Additional certificates / compliance approvals |
CSA C22.2 No. 62368-1, EN 55011, EN 55024, EN 55032, EN 61000-3-2, EN 61000-3-3, EN 61000-4-2 (Electrostatic Discharge), EN 61000-4-3, EN 61000-4-4 (EFT), EN 61000-4-5 (2 kV Surge Protection), EN 61000-4-6, EN 61000-4-8, EN 61000-4-11, TUV 60601, UL 60950-1 |
Fortron Source PM202-15BN1 View full datasheet Close datasheet
|
Medical Power Supplies, 150 W
|
Power Supply |
Efficiency |
At 100% load / 25°C |
91 % |
|
Typ (Output) |
DC |
Range |
28V |
|
|
|
Current |
5,36 A |
|
|
|
Output Ripple & Noise Max |
280 mV |
|
Output wattage |
150 W |
Mechanical / Environment |
Dimensions |
Form factor |
Open Frame (U Bracket) |
|
|
Height |
38 mm |
Certificates / Conformities |
Additional certificates / compliance approvals |
CB, CSA C22.2 No. 62368-1, EN 55011, EN 55024, EN 55032, EN 61000-3-2, EN 61000-3-3, EN 61000-4-2 (Electrostatic Discharge), EN 61000-4-3, EN 61000-4-4 (EFT), EN 61000-4-5 (2 kV Surge Protection), EN 61000-4-6, EN 61000-4-8, EN 61000-4-11, TUV 60601, UL 60950-1 |
Fortron Source PM202-15CN1 View full datasheet Close datasheet
|
Medical Power Supplies, 200 W
|
Power Supply |
Efficiency |
At 100% load / 25°C |
91 % |
|
Typ (Output) |
DC |
Range |
28V |
|
|
|
Current |
7,15 A |
|
|
|
Output Ripple & Noise Max |
280 mV |
|
Output wattage |
200 W |
Mechanical / Environment |
Dimensions |
Form factor |
Open Frame (Housing) |
|
|
Height |
50 mm |
Certificates / Conformities |
Additional certificates / compliance approvals |
CB, CSA C22.2 No. 62368-1, EN 55011, EN 55024, EN 55032, EN 61000-3-2, EN 61000-3-3, EN 61000-4-2 (Electrostatic Discharge), EN 61000-4-3, EN 61000-4-4 (EFT), EN 61000-4-5 (2 kV Surge Protection), EN 61000-4-6, EN 61000-4-8, EN 61000-4-11, TUV 60601, UL 60950-1 |
Fortron Source PM202-16-1BN1 View full datasheet Close datasheet
|
Medical Power Supplies, 150 W
|
Power Supply |
Efficiency |
At 100% load / 25°C |
91 % |
|
Typ (Output) |
DC |
Range |
32V |
|
|
|
Current |
4,69 A |
|
|
|
Output Ripple & Noise Max |
320 mV |
|
Output wattage |
150 W |
Mechanical / Environment |
Dimensions |
Form factor |
Open Frame (U Bracket) |
|
|
Height |
38 mm |
Certificates / Conformities |
Additional certificates / compliance approvals |
CB, EN 55011, EN 55024, EN 55032, EN 61000-3-2, EN 61000-3-3, EN 61000-4-2 (Electrostatic Discharge), EN 61000-4-3, EN 61000-4-4 (EFT), EN 61000-4-5 (2 kV Surge Protection), EN 61000-4-6, EN 61000-4-8, EN 61000-4-11, TUV 60601, UL 60950-1 |
Fortron Source PM202-16-1CN1 View full datasheet Close datasheet
|
Medical Power Supplies, 200 W
|
Power Supply |
Efficiency |
At 100% load / 25°C |
91 % |
|
Typ (Output) |
DC |
Range |
32V |
|
|
|
Current |
6,25 A |
|
|
|
Output Ripple & Noise Max |
320 mV |
|
Output wattage |
200 W |
Mechanical / Environment |
Dimensions |
Form factor |
Open Frame (Housing) |
|
|
Height |
50 mm |
Certificates / Conformities |
Additional certificates / compliance approvals |
CB, EN 55011, EN 55024, EN 55032, EN 61000-3-2, EN 61000-3-3, EN 61000-4-2 (Electrostatic Discharge), EN 61000-4-3, EN 61000-4-4 (EFT), EN 61000-4-5 (2 kV Surge Protection), EN 61000-4-6, EN 61000-4-8, EN 61000-4-11, TUV 60601, UL 60950-1 |
Fortron Source PM202-17BN1 View full datasheet Close datasheet
|
Medical Power Supplies, 150 W
|
Power Supply |
Efficiency |
At 100% load / 25°C |
92 % |
|
Typ (Output) |
DC |
Range |
36V |
|
|
|
Current |
4,17 A |
|
|
|
Output Ripple & Noise Max |
360 mV |
|
Output wattage |
150 W |
Mechanical / Environment |
Dimensions |
Form factor |
Open Frame (U Bracket) |
|
|
Height |
38 mm |
Certificates / Conformities |
Additional certificates / compliance approvals |
CB, CSA C22.2 No. 62368-1, EN 55011, EN 55024, EN 55032, EN 61000-3-2, EN 61000-3-3, EN 61000-4-2 (Electrostatic Discharge), EN 61000-4-3, EN 61000-4-4 (EFT), EN 61000-4-5 (2 kV Surge Protection), EN 61000-4-6, EN 61000-4-8, EN 61000-4-11, TUV 60601, UL 60950-1 |
Fortron Source PM202-17CN1 View full datasheet Close datasheet
|
Medical Power Supplies, 200 W
|
Power Supply |
Efficiency |
At 100% load / 25°C |
92 % |
|
Typ (Output) |
DC |
Range |
36V |
|
|
|
Current |
5,56 A |
|
|
|
Output Ripple & Noise Max |
360 mV |
|
Output wattage |
200 W |
Mechanical / Environment |
Dimensions |
Form factor |
Open Frame (Housing) |
|
|
Height |
50 mm |
Certificates / Conformities |
Additional certificates / compliance approvals |
CB, CSA C22.2 No. 62368-1, EN 55011, EN 55024, EN 55032, EN 61000-3-2, EN 61000-3-3, EN 61000-4-2 (Electrostatic Discharge), EN 61000-4-3, EN 61000-4-4 (EFT), EN 61000-4-5 (2 kV Surge Protection), EN 61000-4-6, EN 61000-4-8, EN 61000-4-11, TUV 60601, UL 60950-1 |
Fortron Source PM202-18BN1 View full datasheet Close datasheet
|
Medical Power Supplies, 150 W
|
Power Supply |
Efficiency |
At 100% load / 25°C |
92 % |
|
Typ (Output) |
DC |
Range |
48V |
|
|
|
Current |
3,13 A |
|
|
|
Output Ripple & Noise Max |
480 mV |
|
Output wattage |
150 W |
Mechanical / Environment |
Dimensions |
Form factor |
Open Frame (U Bracket) |
|
|
Height |
38 mm |
Certificates / Conformities |
Additional certificates / compliance approvals |
CB, CSA C22.2 No. 62368-1, EN 55011, EN 55024, EN 55032, EN 61000-3-2, EN 61000-3-3, EN 61000-4-2 (Electrostatic Discharge), EN 61000-4-3, EN 61000-4-4 (EFT), EN 61000-4-5 (2 kV Surge Protection), EN 61000-4-6, EN 61000-4-8, EN 61000-4-11, TUV 60601, UL 60950-1 |
Fortron Source PM202-18CN1 View full datasheet Close datasheet
|
Medical Power Supplies, 200 W
|
Power Supply |
Efficiency |
At 100% load / 25°C |
92 % |
|
Typ (Output) |
DC |
Range |
48V |
|
|
|
Current |
4,17 A |
|
|
|
Output Ripple & Noise Max |
480 mV |
|
Output wattage |
200 W |
Mechanical / Environment |
Dimensions |
Form factor |
Open Frame (Housing) |
|
|
Height |
50 mm |
Certificates / Conformities |
Additional certificates / compliance approvals |
CB, CSA C22.2 No. 62368-1, EN 55011, EN 55024, EN 55032, EN 61000-3-2, EN 61000-3-3, EN 61000-4-2 (Electrostatic Discharge), EN 61000-4-3, EN 61000-4-4 (EFT), EN 61000-4-5 (2 kV Surge Protection), EN 61000-4-6, EN 61000-4-8, EN 61000-4-11, TUV 60601, UL 60950-1 |