Fortron Source PU1100-14C View full datasheet Close datasheet
|
Open-Frame Power Supplies, 1100 W
|
Power Supply |
Efficiency |
At 100% load / 25°C |
88 % |
|
Output Voltage |
+24V |
Output Current Min. |
0 A |
|
|
|
Output Current Max |
45,84 A |
|
|
|
Regulation Line (±) |
2 % |
|
|
|
Output Ripple & Noise Max |
240 mV |
|
|
+48V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+28V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+36V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+32V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+34V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+42V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
Fortron Source PU1100-15C View full datasheet Close datasheet
|
Open-Frame Power Supplies, 1100 W
|
Power Supply |
Efficiency |
At 100% load / 25°C |
88 % |
|
Output Voltage |
+24V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+48V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+28V |
Output Current Min. |
0 A |
|
|
|
Output Current Max |
39,29 A |
|
|
|
Regulation Line (±) |
2 % |
|
|
|
Output Ripple & Noise Max |
280 mV |
|
|
+36V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+32V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+34V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+42V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
Fortron Source PU1100-16C View full datasheet Close datasheet
|
Open-Frame Power Supplies, 1100 W
|
Power Supply |
Efficiency |
At 100% load / 25°C |
88 % |
|
Output Voltage |
+24V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+48V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+28V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+36V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+32V |
Output Current Min. |
0 A |
|
|
|
Output Current Max |
34,38 A |
|
|
|
Regulation Line (±) |
2 % |
|
|
|
Output Ripple & Noise Max |
320 mV |
|
|
+34V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+42V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
Fortron Source PU1100-17-1C View full datasheet Close datasheet
|
Open-Frame Power Supplies, 1100 W
|
Power Supply |
Efficiency |
At 100% load / 25°C |
89 % |
|
Output Voltage |
+24V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+48V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+28V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+36V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+32V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+34V |
Output Current Min. |
0 A |
|
|
|
Output Current Max |
32,35 A |
|
|
|
Regulation Line (±) |
2 % |
|
|
|
Output Ripple & Noise Max |
340 mV |
|
|
+42V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
Fortron Source PU1100-17C View full datasheet Close datasheet
|
Open-Frame Power Supplies, 1100 W
|
Power Supply |
Efficiency |
At 100% load / 25°C |
89 % |
|
Output Voltage |
+24V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+48V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+28V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+36V |
Output Current Min. |
0 A |
|
|
|
Output Current Max |
30,56 A |
|
|
|
Regulation Line (±) |
2 % |
|
|
|
Output Ripple & Noise Max |
360 mV |
|
|
+32V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+34V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+42V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
Fortron Source PU1100-18-1C View full datasheet Close datasheet
|
Open-Frame Power Supplies, 1100 W
|
Power Supply |
Efficiency |
At 100% load / 25°C |
89 % |
|
Output Voltage |
+24V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+48V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+28V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+36V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+32V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+34V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+42V |
Output Current Min. |
0 A |
|
|
|
Output Current Max |
26,2 A |
|
|
|
Regulation Line (±) |
2 % |
|
|
|
Output Ripple & Noise Max |
420 mV |
Fortron Source PU1100-18C View full datasheet Close datasheet
|
Open-Frame Power Supplies, 1100 W
|
Power Supply |
Efficiency |
At 100% load / 25°C |
89 % |
|
Output Voltage |
+24V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+48V |
Output Current Min. |
0 A |
|
|
|
Output Current Max |
22,92 A |
|
|
|
Regulation Line (±) |
2 % |
|
|
|
Output Ripple & Noise Max |
480 mV |
|
|
+28V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+36V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+32V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+34V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+42V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |