Fortron Source PU400-12B View full datasheet Close datasheet
|
Open-Frame Power Supplies, 300 W
|
Power Supply |
Output Voltage |
+12V |
Output Current Min. |
0,1 A |
|
|
|
Output Current Max |
25 A |
|
|
|
Regulation Line (±) |
2 % |
|
|
|
Output Ripple & Noise Max |
120 mV |
|
|
+15V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+24V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+48V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+18V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+28V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+36V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
Fortron Source PU400-13-1B View full datasheet Close datasheet
|
Open-Frame Power Supplies, 300 W
|
Power Supply |
Output Voltage |
+12V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+15V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+24V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+48V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+18V |
Output Current Min. |
0,1 A |
|
|
|
Output Current Max |
16,67 A |
|
|
|
Regulation Line (±) |
2 % |
|
|
|
Output Ripple & Noise Max |
180 mV |
|
|
+28V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+36V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
Fortron Source PU400-13B View full datasheet Close datasheet
|
Open-Frame Power Supplies, 300 W
|
Power Supply |
Output Voltage |
+12V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+15V |
Output Current Min. |
0,1 A |
|
|
|
Output Current Max |
20 A |
|
|
|
Regulation Line (±) |
2 % |
|
|
|
Output Ripple & Noise Max |
150 mV |
|
|
+24V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+48V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+18V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+28V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+36V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
Fortron Source PU400-14B View full datasheet Close datasheet
|
Open-Frame Power Supplies, 300 W
|
Power Supply |
Output Voltage |
+12V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+15V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+24V |
Output Current Min. |
0,1 A |
|
|
|
Output Current Max |
12,5 A |
|
|
|
Regulation Line (±) |
2 % |
|
|
|
Output Ripple & Noise Max |
240 mV |
|
|
+48V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+18V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+28V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+36V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
Fortron Source PU400-15B View full datasheet Close datasheet
|
Open-Frame Power Supplies, 300 W
|
Power Supply |
Output Voltage |
+12V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+15V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+24V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+48V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+18V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+28V |
Output Current Min. |
0,1 A |
|
|
|
Output Current Max |
10,72 A |
|
|
|
Regulation Line (±) |
2 % |
|
|
|
Output Ripple & Noise Max |
280 mV |
|
|
+36V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
Fortron Source PU400-17B View full datasheet Close datasheet
|
Open-Frame Power Supplies, 300 W
|
Power Supply |
Output Voltage |
+12V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+15V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+24V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+48V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+18V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+28V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+36V |
Output Current Min. |
0,1 A |
|
|
|
Output Current Max |
8,34 A |
|
|
|
Regulation Line (±) |
2 % |
|
|
|
Output Ripple & Noise Max |
360 mV |
Fortron Source PU400-18B View full datasheet Close datasheet
|
Open-Frame Power Supplies, 300 W
|
Power Supply |
Output Voltage |
+12V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+15V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+24V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+48V |
Output Current Min. |
0,1 A |
|
|
|
Output Current Max |
6,25 A |
|
|
|
Regulation Line (±) |
2 % |
|
|
|
Output Ripple & Noise Max |
480 mV |
|
|
+18V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+28V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |
|
|
+36V |
Output Current Min. |
- |
|
|
|
Output Current Max |
- |
|
|
|
Regulation Line (±) |
- |
|
|
|
Output Ripple & Noise Max |
- |